6000 PRC/PRL IP65

SKU: REELS.INDUSTRIAL.6000-PRC-PRL-IP65 Categories: , ,

Technical features

  • Die-cast aluminum structure painted with epoxy powders.
  • Roller cable guide mouth.
  • Cable stop device with rack that can be inserted every 50 cm. All cable reels are supplied with the cable stop device disconnected. Easily insertable.
  • Double ground contact.
  • Collector with brass rings and special brushes with very low voltage drop.
  • Collector insulation voltage 2.5 KV.
  • Sliding contacts with collector ring and brushes.
  • Degree of protection IP65.
  • Ambient operating temperature -5 ° C / + 50 ° C.
  • Supplied with 2 m long power cable section.
  • Optionals and spare parts

    PRC to PRL transformation kit

    Art. 6100

    Optional device to make the hose reel fixed instead of swiveling. Indispensable for ceiling application.


    Art. 949/PR

    Roller type entry for cable reel.


    Essential for ceiling applications.
    Recommended for applications where the cable is not pulled parallel to the cable reel entry

    Art. 953


    Data sheetArt.Number of conductorsCross-section (mm2)Cable length (m)Wound cable capacity (@20°C)Unwound cable capacity (@20°C)Power of wound cable ACable power played AKW wound cableKW cable playedCable typeCable diameter (mm)
    DS_6195___PRC___IP65_UK.pdf6195 / PRC / IP651 X624PVC5.5
    DS_6193_PRC_IP65_314_UK.pdf6193/PRC/IP65/3141 X1617PVC8
    DS_6191___PRC___IP65_UK.pdf6191 / PRC / IP652 X1.5261.1 KW @ 230V1.8 KW @ 230V4.787.821.11.8PVC8
    DS_6189___PRC___IP65_UK.pdf6189 / PRC / IP652 X2.5231.8 KW @ 230V2.5 KW @ 230V7.8210.861.82.5PVC9
    DS_6186___PRC___IP65_UK.pdf6186 / PRC / IP653 G1.5261.1 KW @ 230V1.8 KW @ 230V4.787.821.11.8PVC7
    DS_6186___IP65_RNF_UK.pdf6186 / IP65 RNF3 G1.5221.1 KW @ 230V1.8 KW @ 230V4.787.821.11.8RUBBER (H07RN-F)9.5
    DS_6185___PRC___IP65_UK.pdf6185 / PRC / IP653 G2.5172.0 KW @ 230V3.0 KW @ 230V8.6913.0423PVC10
    DS_6184___IP65_RNF_UK.pdf6184 / IP65 RNF3 G2.5142.0 KW @ 230V3.0 KW @ 230V8.6913.0423RUBBER (H07RN-F)11.5
    DS_6185___IP65_RNF_UK.pdf6185 / IP65 RNF3 G2.5142.0 KW @ 230V3.0 KW @ 230V8.6913.0423RUBBER (H07RN-F)11.5
    DS_6181___PRC___IP65_UK.pdf6181 / PRC / IP654 G1.5231.1 KW @ 400V1.8 KW @ 400V2.754.51.11.8PVC8.5
    DS_6181___IP65_RNF_UK.pdf6181 / IP65 RNF4 G1.5181.1 KW @ 400V1.8 KW @ 400V2.754.51.11.8RUBBER (H07RN-F)10.5
    DS_6521___PRC___IP65_UK.pdf6521 / PRC / IP654 G2.5172.0 KW @ 400V3.0 KW @ 400V57.523PVC11
    DS_6521___IP65_RNF_UK.pdf6521 / IP65 RNF4 G2.5122.0 KW @ 400V3.0 KW @ 400V57.523RUBBER (H07RN-F)12.5
    DS_6067___PRC___IP65_UK.pdf6067 / PRC / IP655801 BY1.5181.5 KW @ 400V2.2 KW @ 400V3.755.51.52.2PVC9.5
    DS_6022___PRC___IP65_UK.pdf6022 / PRC / IP655801 BY2.5122.0 KW @ 400V3.0 KW @ 400V57.523PVC12.5
    DS_6022___IP65_RNF_UK.pdf6022 / IP65 RNF5801 BY2.5102.0 KW @ 400V3.0 KW @ 400V57.523RUBBER (H07RN-F)13.5
    DS_6065___PRC___IP65_UK.pdf6065 / PRC / IP657 X1180.1253PVC8.5
    DS_6069___PRC___IP65_UK.pdf6069 / PRC / IP657 X1.5114.5 A4.5PVC10.5
    DS_6066___PRC___IP65_UK.pdf6066 / PRC / IP658 X1130.1253PVC10
    DS_6070___PRC___IP65_UK.pdf6070 / PRC / IP658 X1.5104.5 A4.5PVC11.5
    DS_6195___PRC___IP65___6100_UK.pdf6195 / PRC / IP65 + 61001 X624PVC5.5
    DS_6195_IP65_314_UK.pdf6195/IP65/3141 X1617PVC8
    DS_6191___PRC___IP65___6100_UK.pdf6191 / PRC / IP65 + 61002 X1.5261.1 KW @ 230V1.8 KW @ 230V4.787.821.11.8PVC8
    DS_6189___PRC___IP65___6100_UK.pdf6189 / PRC / IP65 + 61002 X2.5231.8 KW @ 230V2.5 KW @ 230V7.8210.861.82.5PVC9
    DS_6186___PRC___IP65___6100_UK.pdf6186 / PRC / IP65 + 61003 G1.5261.1 KW @ 230V1.8 KW @ 230V4.787.821.11.8PVC7
    DS_6186___IP65_RNF___6100_UK.pdf6186 / IP65 RNF + 61003 G1.5221.1 KW @ 230V1.8 KW @ 230V4.787.821.11.8RUBBER (H07RN-F)9.5
    DS_6185___PRC___IP65___6100_UK.pdf6185 / PRC / IP65 + 61003 G2.5172.0 KW @ 230V3.0 KW @ 230V8.6913.0423PVC10
    DS_6184___IP65_RNF___6100_UK.pdf6184 / IP65 RNF + 61003 G2.5142.0 KW @ 230V3.0 KW @ 230V8.6913.0423RUBBER (H07RN-F)11.5
    DS_6185___IP65_RNF___6100_UK.pdf6185 / IP65 RNF + 61003 G2.5142.0 KW @ 230V3.0 KW @ 230V8.6913.0423RUBBER (H07RN-F)11.5
    DS_6181___PRC___IP65___6100_UK.pdf6181 / PRC / IP65 + 61004 G1.5231.1 KW @ 400V1.8 KW @ 400V2.754.51.11.8PVC8.5
    DS_6181___IP65_RNF___6100_UK.pdf6181 / IP65 RNF + 61004 G1.5181.1 KW @ 400V1.8 KW @ 400V2.754.51.11.8RUBBER (H07RN-F)10.5
    DS_6521___PRC___IP65___6100_UK.pdf6521 / PRC / IP65 + 61004 G2.5172.0 KW @ 400V3.0 KW @ 400V57.523PVC11
    DS_6521___IP65_RNF___6100_UK.pdf6521 / IP65 RNF + 61004 G2.5122.0 KW @ 400V3.0 KW @ 400V57.523RUBBER (H07RN-F)12.5
    DS_6067___PRC___IP65___6100_UK.pdf6067 / PRC / IP65 + 61005801 BY1.5181.5 KW @ 400V2.2 KW @ 400V3.755.51.52.2PVC9.5
    DS_6022___PRC___IP65___6100_UK.pdf6022 / PRC / IP65 + 61005801 BY2.5122.0 KW @ 400V3.0 KW @ 400V57.523PVC12.5
    DS_6022___IP65_RNF___6100_UK.pdf6022 / IP65 RNF + 61005801 BY2.5102.0 KW @ 400V3.0 KW @ 400V57.523RUBBER (H07RN-F)13.5
    DS_6065___PRC___IP65___6100_UK.pdf6065 / PRC / IP65 + 61007 X1180.1253PVC8.5
    DS_6069___PRC___IP65___6100_UK.pdf6069 / PRC / IP65 + 61007 X1.5114.5 A4.5PVC10.5
    DS_6066___PRC___IP65___6100_UK.pdf6066 / PRC / IP65 + 61008 X1130.1253PVC10
    DS_6070___PRC___IP65___6100_UK.pdf6070 / PRC / IP65 + 61008 X1.5104.5 A4.5PVC11.5