6000 PRL series

 6000 PRL SERIES
TECHNICAL DATA
  • Die-cast aluminium case
  • Cable roller guide
  • Ratchet stop device every 50 cm.All cable reels are supplied with predisposition for cable-stop device off. It can be easily inserted.
  • Double earth contact.
  • Collector insulating power 2,5 Kv.
  • Brass-rings collector and special brushes with minimum impedance drop.
  • Slipring with brass rings and brushes.
  • Protection degree IP43.
  • Working temperature -5°C/+50°C.
  • Delivered without cable at feeding side.
  • Available both with PVC cable and rubber cable.
  Art.
Conductor number
conductor section
Cable length (m)
Ø cable
(mm)
Reinforced collector
Cable type    
  6340/PRL  1 x  2.5  28+2  5.5    H05V-F     
6386/PRL  1 x  24+2  5.5  * H05V-F     
6384/PRL  1 x  16  15+2  * H05V-F     

  Art.
Conductor number
conductor section
Cable length (m)
Ø cable
(mm)
Reinforced collector
Cable type
  6341/PRL  2 x  18+2    H05VV-F  1.7 
  6383/PRL  2 x  24+2    H05VV-F  1.7 
  6382/PRL  2 x  1.5  24+2    H05VV-F  1.1  1.8 
  6380/PRL  2 x  2.5  21+2    H05VV-F  1.8  2.5 
  6378/PRL  3 G  24+2  6,5    H05VV-F  1.7 
  6377/PRL  3 G  1.5  24+2    H05VV-F  1.1  1.8 
  6377/PRL RNF  3 G  1.5  20+2  9,5    H07RN-F  1.1  1.8 
  6375/PRL  3 G  2.5  15+2  10    H05VV-F 
6376/PRL  3 G  2.5  15+2  10  * H05VV-F 
  6375/PRL RNF  3 G  2.5  12+2  11,5    H07RN-F 
  6376/PRL RNF  3 G  2.5  12+2  11,5  * H07RN-F 

  Art.
Conductor number
conductor section
Cable length (m)
Ø cable
(mm)
Reinforced collector
Cable type
  6373/PRL  4 G  24+2    H05VV-F  0.8  1.4 
  6372/PRL  4 G  1.5  21+2  8,5    H05VV-F  1.1  1.8 
  6372/PRL RNF  4 G  1.5  16+2  10,5    H07RN-F  1.1  1.8 
  6370/PRL  4 G  2.5  15+2  11    H05VV-F 
6525/PRL  4 G  2.5  15+2  11  * H05VV-F 
  6525/PRL RNF  4 G  2.5  10+2  12,5  * H07RN-F 
6396/PRL  4 G  8+2  14  * H05VV-F 
  6136/PRL  5 G  16+2  7,5    H05VV-F  0.8  1.4 
  6140/PRL  5 G  1.5  15+2  9,5    H05VV-F  1.5  2.2 
  6154/PRL  5 G  2.5  10+2  12.5    H05VV-F 
6156/PRL  5 G  2.5  10+2  12.5  * H05VV-F 
  6156/PRL RNF  5 G  2.5  8+2  13,5  * H07RN-F 

  Art.
Conductor number
conductor section
Cable length (m)
Ø cable
(mm)
Cable type Max
Current
(A)
 
  6138/PRL  7 x  16+2  8,5  H05VV-F   
  6142/PRL  7 x  1.5  9+2  10,5  H05VV-F  4.5   
  6139/PRL  8 x  11+2  10  H05VV-F   
  6143/PRL  8 x  1.5  8+2  11,5  H05VV-F  4.5   
  6196/PRL  8 x  2.5  6+2  14  H05VV-F  7.5   
  6144/PRL  10 x  8+2  13  H05VV-F   
  6146/PRL  10 x  1.5  6+2  15,5  H05VV-F  4.5   
  6614/PRL  12 x  10+2  13  H05VV-F   
  6616/PRL  12 x  1.5  6+2  13,5  H05VV-F  4.5   
  6145/PRL  16 x  6+2  14  H05VV-F   

OPTIONAL
ART. 949/PR
Optional device to make the fastening bracket of PRC series 
cable reels fixed instead of pivoting.